The Challenge Carbonation of reinforced concrete is one of the most common forms of deterioration in buildings and infrastructure. Carbon dioxide from the atmosphere reacts with the concrete, leading to a loss of alkalinity and subsequent corrosion of the reinforcing steel. Structural integrity can therefore become severely compromised so it...
The Challenge After prolonged usage, certain areas of the pump were suffering from cavitations damage, which in turn was hindering the efficiency of the pumping system. The Solution MRO 1011 Kleaner Degreezer MRO 8000 Ti Putty MRO 3003 Brushable Ceramic MRO 3004 Super Glide APPLICATION METHOD Firstly, all machined...
The Challenge Small leakages in tanks and Chemical Containment areas caused damage to the external paint and resulted in corrosion and additional leakages. The Solution MRO 1011 Kleaner Degreezer MRO 8051 S Stick MRO 8000 Ti Putty MRO 3000 Chempro APPLICATION METHOD: From the leakage area loose metal was...
The Challenge Prevent cold welding, galling and failure of threaded connections, tightened to extremely high torque levels The Solution Replace a traditional paste, which was being squeezed out of the high-torque connections and causing thread failures, with ‘MRO 7001 Cu ANTISIEZE’ a more durable solid-film lubricant. The Result ‘MRO 7001...
The Challenge Vibrators used to de-air material were shaking off grease, causing premature bearing failure. Operations had to be stopped while the bearings were replaced. The Solution ‘MRO 7004 ROLLER BEARING GEL’ is formulated to perform under heavy loads, reducing the coefficient of friction and metal to-metal contact, minimizing wear...
The Challenge Preventing & protecting electric power cables & JB (Junction Boxes) against ignition & propagation of Fire. To be able to access the escape routes & power supply for a longer time during a fire The Solution ‘MRO 5001 KF 600’ a single part non flammable water based coating...
The Challenge Electric motor customer uses insulation tester to measure the resistance of motor winding with earthing. The challenge is when IR value is found low. The Solution ‘MRO 1006 RED INSULATION VARNISH KOTE’ provides an insulation coating which is Class F, air drying and in a conveniently packed Aerosol....
The Challenge Increase efficiency Increase reliability Improve safety Reduce cost The Solution Prevented leakages by repairing damaged metal surfaces: MRO 1011 KLEANER DEGREEZER MRO 8001 S PUTTY MRO 8051 S STICK The Result • Increased Productivity • Improved efficiency • Reduced chronic failures • Increased uptime • Extended asset life...
The Challenge Extended Breakdown/Shutdown time due to delay in opening seized assemblies like: Corroded Fastener Equipment disassembly Bearings Chains Conveyors Nuts and Bolts Pulleys Screws Shafts Hinges The Solution ‘MRO 1010 PEN OIL’ is a low surface tension penetrant that attacks rust and frees seized parts quickly and its unique...
The Challenge Removing below listed stains from substrates like walls, floorings, carpets, garment etc Betel nut Crayons Spilled Mascara, Nail Polish, lipstick, Paint and Scuff Marks Gooey residues from price tags, duct tape and stickers. Gum from carpets The Solution Spray liberally ‘MRO 1000 MEKANIK’. Allow it to penetrate. If...